型 | OCA- H300BC-AW2 | OCA- H600BC-AW2 | OCA- H1000BC-AW2 | OCA- H1600BC-AW2 | OCA- H2200BC-AW2 | OCA- H2900BC-AW2 | |
安装类型 | 横向安装 | ||||||
冷却能力 *1 | 250/300W | 500/610W | 800/1000W | 1450/1600W | 2000/2200W | 2600/2900W | |
额定电压(50/60Hz) *2 | 单相 200 至 240VAC | ||||||
额定消耗电流*3 | 200V | 1.2/1.*** | 2.1/2.7A | 2.9/3.7A | 3.4/4.4A | 5.0/5.3A | 6.6/7.8A |
220V | 1.3/1.*** | 2.3/2.7A | 3.1/3.7A | 3.4/4.*** | 5.8/5.1A | 6.7/7.4A | |
240V | 1.5/1.*** | 2.8/2.7A | 3.5/3.6A | 3.4/4.*** | 7.4/5.1A | 7.4/7.1A | |
消耗电流*3 | 1.6/1.7A | 3.0/3.0A | 4.0/4.3A | 4.2/5.2A | 8.0/6.8A | 9.1/10.8A | |
启动电流 | 4.9/4.6A | 10.3/10.1A | 14.5/13.8A | 20.7/19.1A | 33.3/31.4A | 38.1/34.1A | |
额定功耗 *3 | 200V | 230/270W | 410/440W | 570/690W | 660/800W | 930/1050W | 1290/1540W |
220V | 260/310W | 490/490W | 650/760W | 720/860W | 1070/1110W | 1380/1590W | |
240V | 320/340W | 620/550W | 750/840W | 790/930W | 1300/1210W | 1550/1670W | |
功耗 *3 | 350/380W | 690/630W | 890/970W | 950/1170W | 1530/1480W | 1970/2190W | |
工作温度 *3 | +20 至 +50°C | ||||||
工作湿度 | 不超过85%相对湿度,无冷凝 | ||||||
噪声 | 63分贝 (A) | 64分贝 | 65分贝 | 66分贝 | 66分贝 | 66分贝 | |
温度设定范围 *3 | +30 至 +45°C(默认 +35°C) | ||||||
显示 | 内部温度/报警代码/操作指示灯(绿色)/报警灯(红色) | ||||||
功能 | 关温报警、异常散热检测、温度传感器断开检测、 维护提醒、强制冷却操作进行检查 | ||||||
报警输出 | 无电压触点输出 1A x 2 (普通) 250VAC 2A 30VDC 2A | ||||||
通讯功能 | RS485 2线制系统(Modbus RTU) | ||||||
抗振性 | 振动频率10至55Hz,振幅0.15mm,扫描周期10次 | ||||||
防护等级 *4 | 内部电路IP54等效 | ||||||
符合标准 | 电磁兼容指导 | EN61000-6-4, EN61000-6-2 | |||||
低电压指令 | EN60335-1, EN60335-2-40 | ||||||
UL标准 | UL60335-1, UL60335-2-40 | ||||||
CCC 标准 | GB4706.1、GB4706.32、GB4343.1、GB17625.1 | ||||||
环境 | RoHS2 | ||||||
冷却剂 | R1234yf (130克) | R1234yf (280克) | R1234yf (500g) | R1234yf (780g) | R1234yf (1000g) | R1234yf (1100g) | |
全球升温潜能值 *5 | <1 | ||||||
颜色 | 粉末涂料对应N8,对应N4 | ||||||
尺寸(毫米)*6 | 宽300×H500 ×D150 | 宽300×H550 ×D200 | 宽350×H900 ×D200 | 宽390×H950 ×D220 | 宽450×H1150 ×D220 | 宽450×H1350 ×D220 | |
重量 | 16.0公斤 | 20.0公斤 | 33.0公斤 | 41.0公斤 | 50.0公斤 | 62.0公斤 |