The MVI56 PROFIBUS DP Slave Communication Module allows Rockwell Automation ControlLogix I/O compatible processors to interface easily with a PROFIBUS DP Master device. Features and Benefits The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the module and Rockwell Automation ControlLogix processors. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. The MVI56 module Configuration/Debug Serial port connects a PC to the module for configuration, status, monitoring, and troubleshooting (Serial cable is included with product shipment). After editing on a PC, a configuration file is downloaded and stored on the MVI56 module. The PROFIBUS DP Slave gives access to the unit's input and output images with up to 244 bytes of Input and Output data, for a maximum of 400 bytes total. These Input and Output data blocks are mapped by the user within the inRAx module's data memory allowing maximum flexibility and data transfer with other protocols.
Single Slot – 1756 backplane compatible • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module • Ladder Logic is used for data transfer between module and processor. Sample ladder file included. • Configuration data obtained from configuration text file downloaded to module. Sample configuration file included • Local or remote racPROFIBUS Slave • Communication parameters o Baud Rate: 9.6 kbit/s12 Mbit/s • Supported I/O length o Up to 244 bytes Input data o Up to 244 bytes Output data o Total not to exceed 400 bytes. • Freeze Mode • Sync Mode • Auto Baud Setting o Configurable Parameters o PROFIBUS Node Address: 0 to 125 o Data byte swapping o Action on loss of PROFIBUS connection o Comm Fail Timeout Multiplier o Status Data location in Internal Database • Status Data o PROFIBUS Status Data for slave • Physical Connection o PROFIBUS Connector o Standard PROFIBUS DB-9F communication connector. Cable connection matches PROFIBUS pin out specification.
————————深圳长欣自动化设备有限公司——————————
APV Invensys Plate Frame Heat Exchanger R5 621 sq ft SS
Western Gear Increaser 4113-IHS High Speed Unit 9000 HP
Square D QED 4x NEF Breaker Panel 4000 Amp A 4W Ground
Allen Bradley AB SMC Plus Soft Start 300 HP Pump Panel
Square D NE NEF361200LSG 1200 Amp 1200A A LSIG
Square D NE NEF361200LSG 1200 Amp 1200A A LSIG
Square D Enclosed 48 Soft Start Altistart 8839 400 HP H
GE AKR-10D-125 5000 A Amp Breaker MVT Plus Trip 635 V
ASCO 1200 Amp G9623120097XC Transfer Switch 480/277 4W
Square D QED Breaker Panel 2x PEF361600LS 1600 Amp A 4W
Square D NE NEF36800LSG 800 Amp 800A A LSIG
Square D QED BPO364 Bolt Loc Panel 4000 Amp A 4W Ground
Fanuc Model 10LH A06B-0615-B383-R DC Servo Motor REM
Cutler Hammer CH Advantage W240M6CFC Sz Size 6 MCCB
Bell Gossett Plate Frame Heat Exchanger GPX 807 1057 sq
Square D New EZ Meter Pak EZM11600CB 3R Meter Center
Toshiba VFAS14132KPCA1 Inverter VF-AS1 VS Drive 200 HP
Square D QED 2x NEF Breaker Panel 4000 Amp A 4W Ground
NWL Transformer 260 kVA 460 500/24000 27000 260kVA oil
ITE GOULD BBC ABB K3000 K 3000 3000A Air Breaker LS
Cutler Hammer CH Advantage W240M6CFC Size Sz 6 Starter
=