各品牌DCS;PLC停产备件模块
本公司:
PLC、DCS系统备件 模块
〖⒈〗Allen-Bradley(美国AB)系列产品》
〖⒉〗(莫迪康电气)系列产品》
〖⒊〗General electric(通用电气)系列产品》
〖⒋〗Westinghouse(美国西屋)系列产品》
〖⒍〗销售ABB Robots. FANUC Robots、YASKAWA Robots、KUKA Robots、Mitsubishi Robots、OTC Robots、Panasonic Robots、MOTOMAN Robots
〖⒎〗estinghouse(西屋): OVATION系统、WDPF系统、MAX1000系统备件。
〖⒏〗Invensys Foxboro(福克斯波罗):IA Series系统,FBM(现场输入输出模块)顺序控制、梯形逻辑控制、事故追忆处理、数模转换、输入输出信号处理、数据通信及处理等。Invensys Triconex冗余容错控制系统、基于三重模件冗余(TMR)结构的现代化的容错控制器。
〖⒑〗Bosch Rexroth(博世力士乐):Indramat,IO模块,PLC控制器,驱动模块等。
〖⒒〗Motorola(摩托罗拉):MVME 162、MVME 167、MVME1772、MVME177等系列。
深圳长欣是一家专注于电气工程和工业自动化的备件批发商。深圳长欣与众多制造商合作,专注于提供零部件,原始设备制造商,面板制造商,行业和终用户的停产部件解决方案
在B-to-B电气产品拥有市场,在其市场中为客户提供帮助
通过遍布65个5大洲的密集网络,开发了停产部件解决方案,致力于将价值的工业备件以及服务更贴近客户
我们很自豪成为工业零部件标准制定者
The following additional single width I/O modules are supported by the PACSystems RX7i: Analog Input, 64 Channel, 16 bit resolution, Voltage (IC697VAL264) Analog Input, 12 bit, 32 Channel single-ended or 16 Channel Differential (IC697VAL132) Analog Output, 32 Channel, 12 bit (IC697VAL301) Digital Input, 64 Point (IC697VDD100) Relay Output, 64 Point (IC697VDR151) Digital Output, 64 Point (IC697VDQ120) Eight Channel RTD/Strain Bridge (IC697VRD008) Insulating Strips for High Voltage Modules An insulator strip is required on a high voltage module that is installed to the immediate right of a module with a metal faceplate. Insulating strips should be installed on the following modules that have versions earlier than: IC697MDL240D IC697MDL241D IC697MDL250G IC697MDL251E IC697MDL640E IC697MDL340G IC697MDL341E IC697MDL350F Note: Current versions of these modules are shipped with the insulators installed. The strip is visible on the back of the printed wiring assembly. The RX7i rack is shipped with an Insulator Kit that includes enough parts to update three Series 90-70 I/O modules. Ethernet Functional Compatibility Subject Description RX7i Does Not Support SRTP Client (“Channels”) The Ethernet Interface does not support the SRTP Client operation (“SRTP Channels”) that was provided in the Series 90-70 Ethernet Interface (IC697CMM742). SRTP and EGD Performance Differs from Series 90-70 SRTP and EGD performance in the RX7i differs slightly from the Series 90-70. Each RX7i Ethernet Interface supports a greater number of SRTP connections and EGD exchanges. Please also note that the RX7i currently has several SRTP and EGD operational restrictions when compared to the Series 90-70. When migrating Series 90-70 Ethernet applications to the RX7i, please carefully read the "Ethernet Operational Notes” section on page 19. Series 90-70 LAN Interface Modules (IC697CMM741 and IC697CMM742) not Supported by RX7i Please note that the Series 90-70 LAN Interface Modules (IC697CMM741 and IC697CMM742) are not supported by the RX7i and should not be placed in an RX7i rack. The RX7i CPU contains an embedded Ethernet Interface. If additional Ethernet Interfaces are required, the RX7i Ethernet Module (IC698ETM001) should be used.