产品标题: 23KT92 GJR5250500R5101工控系统PLC/DCS卡件模块自动化设备
型号:23KT92 GJR5250500R5101
品牌:ABB
产品图片展示
产品详情资料:
23KT92 GJR5250500R5101在正常操作过程中,应将输入功率保持在建议的输入电压范围内。建议仅在短时间内在扩展电压范围内操作。注意尽量减少由冗余电源的断开/接通开关引起的输入瞬态。当电源负载增加到Tricon控制器电源模块要求的***时,不要让电源下降到***输入电压(19.2 VDC)以下,23KT92 GJR5250500R5101或者当负载减少到Tricon控制电源模块要求40%至60%时,不要使电源上升到电压(36 VDC)以上。例如,假设输入接线的电压损失最小,电源为24V±5%,则对电源的瞬态响应不应超过这些限制。230伏电源模块规格此表列出了8312型的规格,该型号为230伏交流电电源模块。1000伏交流电或1500伏交流电,输入到输出标称输入电压230 VAC(-15%到+10%)扩展输入电压范围185到285 VAC低线路开/关滞后15 VAC输入功率要求每个电源至少240 W输入频率47到63 Hz功率因数0.70典型波峰因数2.5典型输入电流稳态0.4安培,典型;1.2安培,In rush(1/2 AC循环)18安培@230 VAC输入保险丝额定值和类型2.5安培,延时输出电压6.5 VDC,在所有操作条件下±1%环境温度为140°F(60°C)时输出电流最小27安培,23KT92 GJR5250500R5101
指的是在底盘底部测得的空气温度。140°F(60°C)环境温度下的输出功率175瓦输出保持时间@0伏输入最小20ms;80 ms典型输出过电压保护125%,典型,循环电源重新启动输出过电流限制140%,典型自动重新启动过热警告传感器当内部电源模块温度高于181°F(83°C)时,温度监测器跳闸。通常发生在140°F(60°C)或更高的环境温度下。
产品英文详情料:
During normal operation, you should keep the input power within the recommended input voltage range. Operation in the extended voltage range is advisable only 23KT92 GJR5250500R5101for short periods of time. Be careful to minimize input transients which are caused by the off/on switching of the redundant power source. Do not allow the power source to drop below the minimum input voltage (19.2 VDC) when its load increases to *** of the Tricon controller power module requirements, or rise above the maximum voltage (36 VDC) when the load decreases to 40 to 60% of the Tricon controller power module requirements. For example, assuming minimal voltage losses to the input wiring and a power source of 24V ±5%, the transient response to the power source should not exceed these limits.230 Volt Power Module Specifications This table lists the specifications for model 8312, which is a 230 VAC Power Module.1000 VAC or 1500 VDC, Input to Output Nominal input voltage 230 VAC (–15% to +10%) Extended input voltage range 185 to 285 VAC Low line on/off hysteresis 15 VAC Input power required 240 W minimum per power source Input frequency23KT92 GJR5250500R5101 47 to 63 Hz Power factor 0.70 typical Crest factor 2.5 typical Input current Steady-state 0.4 amps, typical; 1.2 amps, maximum In-rush (1/2 AC cycle) 18 amps maximum @ 230 VAC Input fuse rating and type 2.5 amps, time-delay Output voltage 6.5 VDC, ±1% under all operating conditions Output current 27 amps minimum at140° F (60° C) ambient, which refers to the air temperature measured at the bottom of the chassis. Output power 175 watts at 140° F (60° C) ambient Output hold time @ 0 volts input 20 ms minimum; 80 ms typical Output over-voltage protection 125%, typical, recycle power to restart Output over-current limit 140%, typical, auto restart Over-temperature warning sensor Temperature monitor trips when the internal power module temperature is greater than 181° F (83° C). Typically occurs at an ambient temperature of 140° F (60° C) or higher.23KT92 GJR5250500R5101
公 司 优 势