供应COMDEL CLF500H射频电源维修及销售
¥10000.00
***的制程正常运行时间
更高的操作简易性和灵活性
无需定制组件提前期的定制化性能
长期的使用简易性,节省成本
精簡的流线型设计
标准的平台包装
高效率——低发热量
200和400 VAC 的输入选择
两个模拟用户端口选择
RS-232、以太网及 Profibus 通讯
多功能前面板
便利、全面的操作菜单
CEX(相位同步)操作模式
CESAR? 1310 RF GENERATOR | ||||||||
Specification | ||||||||
Frequency | 13.560 MHz +/- 0.005% | |||||||
Max output power | 1000 W into a 50 ? load | |||||||
Min output power | 10 W into a 50 ? load | |||||||
Reflected power limit | 200 W | |||||||
Delivered power into mismatch | 20% depending on the load impedance | |||||||
Load impedance | 50 ? | |||||||
RF connector | 50 ?, N-type, female | |||||||
RF power regulation mode | P forward, P delivered, or DC selfbias voltage | |||||||
Regulation (of set point) | 1.0 or 0.1% of full-rated power, whichever is greater, into a 50 ? load | |||||||
Response time (ms) | Consult factory. | |||||||
Turn off/decay time (ms) | Consult factory. | |||||||
Harmonics | -50 dBc at full-rated power | |||||||
Spurious content | -60 dBc max at full-rated power | |||||||
Pulse mode | Yes | |||||||
Pulse repetition frequency | 1 to 30 kHz | |||||||
Consult factory. | ||||||||
Pulse duty cycle | 1% to *** | |||||||
Consult factory. | ||||||||
Pulse RF envelope rise / fall time (ms) | Consult factory. | |||||||
CEX operation mode | Yes | |||||||
CEX input signal as required | 0 to +10 dbm | |||||||
CEX output signal specifications | +3 to +10 dbm | |||||||
CEX connector (50 ?) | BNC, female | |||||||
Display | LCD graphic display | |||||||
256 x 132 dots , black / white | ||||||||
Interlocks and Limits | ||||||||
Reflected power | Yes | |||||||
Overtemperature | Yes | |||||||
Current limit | Yes | |||||||
DC overload | Yes | |||||||
RF power limit | Yes | |||||||
Cooling | ||||||||
Cooling | Air cooling | |||||||
Air cooling requirement | 118 m/h3 | |||||||
AC Power Line | ||||||||
AC line voltage (1-phase) | 110 VAC/230 VAC (187 AC to 253 VAC) | |||||||
AC line frequency | 50/60 Hz | |||||||
AC line current (per phase) | 6.5 A nominal line, full power | |||||||
AC input power | 1490 VA | |||||||
Overcurrent limit (per phase) | 10 A to be created by user through fuse or circuit breaker | |||||||
Efficiency line to load | 66% at full power, nominal line | |||||||
Power factor | 97% to *** at max power | |||||||
AC mains connection | IEC 320 at full power | |||||||
Physical Specification | ||||||||
Packaging | 19" rack cabinet | |||||||
Mounting | 19" rack mounting | |||||||
Weight | 19.5 kg (43 lb) | |||||||
Clearance | 60 mm (2.36") on each side for air flow into unit | |||||||
Dimensions | 88 mm (H) x 483 mm (W) x 500 mm (D) | |||||||
3.46" (H) x 19" (W) x 19.69" (D) |