VE3006 KJ2003X1-BB1
VE3006 KJ2003X1-BB1
CE声明-基本标准
EMC(欧洲协调标准)
EMC-Directive 2004/108 / EC
EN 55022 ITE的排放
- IEC/EN 61000-6-2 -工业环境中的抗扰度
EN 61000-3-2 -谐波电流发射限值
EN 61000-3-3 -电压变化限制;
电压波动和闪烁安全(协调)
符合欧洲低压指令标准
2006/95 / EG)
- EN 61131-2 -可编程控制器
A类A类A类A类A类A类A类
FCC宣言
- CFR47***5部分
A类A类A类A类A类A类A类
UL 508认证
- UL 508 -工业控制设备
我们。安全标准
- CSA 22.2 No. 142-M1997 -工业控制设备
-加拿大安全标准
是是是是是是是
根据ISA-12.12的cUL批准。-01 1班
分区2 /UL1604
- ANSI/ISA 12.12.01 2001年批准
- CSA 22.2第213-M1987号
是是是(1)是(1)否
IEC/EN 61131-2声明
- EN 61131-2 -可编程控制器
是是是是-否否
UL 60950-1认证
- UL 60950-1——信息安全
技术设备-
我们。安全标准
- CSA 22.2第950号-资讯科技安全
设备。加拿大安全标准
- /A - /A - /A是是
IEC/EN 60950-1 CB-scheme认证(2)
EN 60950-1 -信息技术
ATEX 100a Approval, Zone 2,
- according to EN 60079-0 and EN 60079-15 - Electrical
apparatus for explosive atmospheres
N/A Yes N/A Yes(3) N/A No
DNV-GL No Yes No Yes(3) No Yes(3)
RCM (Australia) Yes Yes Yes Yes Yes Yes
EAC (Russia): pending Yes Yes Yes Yes Yes Yes
EAC Ex (Russia): pending N/A Yes N/A Yes(3) N/A No
(3) The VE6050T09, VE6050T010 and VE6050T011 SFP transceivers cannot be used with MD20/30 switches when installed in hazardous areas (Zone 2). The same restrictions apply
to the certifications: DNV-GL and EAC Ex which are not available for these SFP transceivers when used with MD20/30 and RM1040 switches.
DeltaV Configuration Parameters
The DeltaV Smart Switches are designed to plug-and-play within the DeltaV network without requiring configuration of the
switching functions to meet DeltaV requirements. As such all of the switching configuration parameters are preset and not
user changeable. To maintain the plug-and-play capability of the switches user administrator access to the switch is restricted
to adjusting the specific parameters listed in this table.
This table provides a list of the configuration parameters that are user accessible and can be changed using the Network Device
Command Center or the Setup Wizard. All other switch configuration parameters are pre-configured and not user accessible.
If the parameter is not on this list it is not accessible to be user configured.
Parameter Description
Reset Configuration
to DeltaV Defaults
Clears the information in the questions below back to DeltaV default values. This command
is only available using the serial port.
IP Address for the Switch
(010.X.x.x)
Network address for the switch to enable DeltaV Smart Switch Command Center access.
Entry must be in the range of permitted DeltaV addresses reserved for switches. The DeltaV
Smart Switches cannot accept any IP address except those used within the DeltaV network.
The subnet mask is set to 255.254.0.0 for DeltaV and is not user configurable.
Name for Switch
[up to 64 Characters]
Name for switch that appears in Network Device Command Center.
Location For Switch
[up to 64 Characters]
Physical location description appears in Network Device Command Center.
Disable Network Discovery Used for setup of switches to be installed in DeltaV v10.3 or v10.3.1 only. This command
disables the switch discovery access that is needed for v11 and newer systems. It should be
disabled in v10 systems as a security measure.
Change Admin Password Allows default switch admin password to be changed – only impacts access to Setup wizard.
Password can only be reset through the DeltaV Wizard or DeltaV Passwords commands
using the serial port, Telnet or SSH connections.
Changing this password only impacts user access to the switch and is not connected or
synchronized with the DeltaV or Windows passwords