经销美国杜邦TEFZEL ETFE HT-2183***6
Density / Specific Gravity | 1.70 | g/cm | ASTM D792 |
Apparent (Bulk) Density | 1.30 | g/cm | Internal Method |
Melt Mass-Flow Rate (MFR)(297°C/5.0 kg) | 6.0 | g/10 min | ASTM D3159 |
Water Absorption(24 hr) | 7.0E-3 | % | ASTM D570 |
Hardness | Nominal Value | Unit | Test Method |
Durometer Hardness(Shore D) | 67 | ASTM D2240 |
Mechanical | Nominal Value | Unit | Test Method |
Tensile Strength(23°C) | 40.0 | MPa | ASTM D638 |
Tensile Elongation(Break, 23°C) | 300 | % | ASTM D638 |
Flexural Modulus(23°C) | 1000 | MPa | ASTM D790 |
Impact | Nominal Value | Unit | Test Method |
Notched Izod Impact(23°C) | No Break | ASTM D256 |
Thermal | Nominal Value | Unit | Test Method |
Melting Temperature | 255 to 280 | °C | ASTM D3418 |
CLTE - Flow(0 to 100°C) | 1.3E-4 | cm/cm/°C | ASTM D696 |
Maximum Service Temperature | 155 | °C | UL 746 |
Electrical | Nominal Value | Unit | Test Method |
Volume Resistivity | 1.0E+17 | ohms·cm | ASTM D257 |
Dielectric Strength(0.250 mm) | 70 | kV/mm | ASTM D149 |
Dielectric Constant(23°C, 1 MHz) | 2.50 to 2.60 | ASTM D1531 | |
Dissipation Factor(23°C, 1 MHz) | 7.2E-3 | ASTM D1531 | |
Flammability | Nominal Value | Unit | Test Method |
Flame Rating | V-0 | UL 94 |