富士豪压缩机B1.5-9.1Y 1.5HP 1.1Kw 半封闭活塞
¥4000.00
压缩机型号 | 汽缸数 | 排气量 m3/h 50Hz | 额定功率 (HP) | 工作电流 400V/50Hz(A) | 堵转电流/锁定转子电流 400V/50Hz(A) | 连接管 (valves with solder conn.) | 重量 (kg) | ||||
低压管 | 高压管 | ||||||||||
LP | HP | mm | inch | mm | inch | ||||||
S5-26.15Y | 4 | 25.22 | 16.4 | 5 | 14.0 | 35.5 | 35 | 1-3/8 | 22.2 | 7/8 | 120 |
S5-26.15Y | 4 | 26.87 | 19.13 | 8 | 18.0 | 47.0 | 35 | 1-3/8 | 22.2 | 7/8 | 122 |
S5-26.15Y | 4 | 41.91 | 29.42 | 10 | 23.0 | 53.9 | 35 | 1-3/8 | 28.6 | 1-1/8 | 173 |
S5-26.15Y | 6 | 58.84 | 29.42 | 15 | 31.0 | 74.8 | 42 | 1-5/8 | 35 | 1-3/8 | 220 |
S5-26.15Y | 6 | 70.77 | 35.39 | 20 | 37.0 | 96.7 | 42 | 1-5/8 | 35 | 1-3/8 | 225 |
S5-26.15Y | 6 | 83.81 | 41.91 | 25 | 45.0 | 104.0 | 42 | 1-5/8 | 35 | 1-3/8 | 230 |
Z30-102.51Y | 6 | 102.92 | 51.46 | 30 | 53.0 | 111.0 | 54 | 2-1/8 | 35 | 1-3/8 | 239 |
压缩机 | 系列 | A-B-D | Q | S | V | Z | W |
汽缸数 | 2 | 4 | 6 | 8 | |||
电机为直接启动[DOL],电机绕组配有PTC热敏电阻 220一240V/380一420V/3/5OHz /// 265一290V/440一480V/3/60Hz | ● | ● | |||||
电机为分绕组启动[PWS],电机绕组配有PTC热敏电阻 380一420V/3/5OHz /// 440一480V/3/6OHz | ● | ● | ● | ● | |||
电子控制单元T00ECA01(电机绕组温度监测) | ● | ||||||
电子控制单元T00ECA01 D(电机绕组温度监测与诊断) | ○ | ● | ● | ||||
电子控制单元T00ECA01 D(电机绕组与排气温度监测与诊断) | ● | ● | ● | ||||
可逆式强制润滑油泵 | ● | ● | ● | ||||
Kriwan电子油压差开关 | ● | ● | ● | ||||
充注POE油(多元醇醋油) | ● [32cSt] | ● [32cSt] | ● [32cSt] | ● [32cSt] | ● [32cSt] | ● [32cSt] | |
曲轴箱加热器[230V,其他电压需订制] | ○ [50W] | ○ [50W] | ○ [70W] | ○ [70W] | ○ [150W] | ○ [150W] | |
光电油位控制器[T00WK252] | ○ | ○ | ○ | ○ | ○ | ○ | |
油位调节器T00EC1900 [230V] | ○ | ○ | ○ | ○ | ○ | ○ | |
排气温度传感器 | ○ | ○ | ● | ● | ● | ||
能量调节[230V线圈,其他电压需订制] | ○ *** 50% | ○ *** 50% | ○ *** 50% | ○ *** 50% | ○ *** 50% | ||
卸载启动[230V线圈,其他电压需订制] | ○ | ○ | ○ | ○ | ○ | ||
吸气与排气阀 | ● | ● | ● | ● | ● | ● | |
附加冷却缸头风扇[230V] | ○ [SZ-FM1] | ○ [SZ-FM9] | ○ [SZ-FM2S] | ○ [SZ-FM2V] | ○ [SZ-FM3] | ○ [SZ-FM4] | |
法兰+油平衡阀 | ○ | ○ | ○ | ○ | ○ | ○ | |
橡胶减震垫(其他尺寸与硬度需另行定制 | ● [30x30] [45Sh] | ● [40x40] [45Sh] | ● [50x50] [55Sh] | ● [30x50] [55Sh] | ● [50x40] [55Sh] | ● [50x40] [55Sh] | |
ATEX压缩机[113GExc11BT3指令1999/92/CE和94/9/CE] | ○ | ○ | ○ | ○ | ○ | ○ |
如何计算在特定工作条件下可能的压缩机频率?
在每一个特定的压缩机和制冷剂的使用限制内的每个工作点,VS压缩机可以达到的频率可用下面公式计算:
f(Max) = MRA x 50Hz / le
f(Max)=允许频率(Hz) MRA=工作电流(A) le=在50Hz的工作电流(A)
不同频率的相对制冷量,可参考以下公式:
Qo(f)factual x Qo50Hz / 50Hz
Qo(f)=在选定的频率的制冷量(W) factual=使用于压缩机的实际频率(Hz) Qo50Hz=在50Hz的制冷量(W)